Silicone Neutral

Preparation

Working Conditions: Use only at temperatures between +5°C and +40°C.
Preliminary treatment: For a neat result, use masking tape along sides of joint. To avoid trhee-sided bonding, first fill joint with foam backer rod or PE foil.
Tools: Use sealant gun to handle cartridge.

Application

Coverage: 1 cartridge for approx. 8m, joint size 6x6 mm
Handling of packaging: Use sealant gun to handle cartridge Open cartridge by cutting off plastic nipple above screw thread with a sharp knife. Attach nozzle to cartridge and cut it slantwise at desired bead size.
Directions for use: Ensure joint width is between 6 mm and 20 mm. Joint depth depends on joint width. Up to 12 mm, keep to a joint depth of 6 mm. Above that, joint depth is half the size of joint width. Fill joint evenly with sealant and tool within 10 minutes using a putty knife or Bison Silicone Multitool wetted with a soap solution. Remove masking tape immediately after tooling. A surface skin will appear after approx. 15 minutes. Cured silicone sealant can only be removed mechanically. For aquariums, use only Bison Silicone Glass.
Stains/Residue: Remove fresh stains immediately with white spirit. Cured sealant can only be removed mechanically.
Points of attention: Silicones cure under the influence of air humidity. Contact with air humidity is therefore essental during curing. Always ensure joint is at least 6 mm wide. For perfectly smooth joints, mask areas adjacent to joint with masking tape. Remove tape immediately after tooling.

Cure times

For detailed information about the cure times, see the Technical Documentation.

Bison uses cookies.

Close
Click here for more information.